LoRaWAN integration kit
Turnkey wireless edge node with decoder documentation. Prefer a sensing probe when you already have a logger or Modbus master—see complementary SKUs below.

LoRaWAN Inline Water Flow Meter (PS-260)
Model: PS-260
An inline LoRaWAN water flow meter reports volume flow in L/min for building branches and process lines you can isolate for installation. The PS-260 combines a pulse or magnetic flow element with a battery-powered LoRaWAN node and decoder-mapped engineering units — no separate pulse counter wiring back to a panel. Building operators choose PS-260 when they need branch-level consumption trends — makeup water, circulation loops, or light process feeds — not just wet/dry leak state. The inline element installs on isolatable pipe sections with documented straight-run requirements in the installation guide.
Key Features
Manufacturer
ParticleSensing
Certification
ISO 9001 / CE
What is an inline LoRaWAN flow meter?
Inline flow meters install in a pipe run and measure the rate water passes through the bore. PS-260 targets DN15–DN50 class branches where utilities teams need trend data — makeup water, circulation loops, or process feeds — not custody transfer. The LoRaWAN node scales pulses to L/min (or m³/h) in the decoder profile so historians receive meaningful units. Install on isolatable sections with straight-run requirements per the datasheet.
Respect straight-run requirements upstream and downstream of the meter — distorted flow profiles from nearby elbows skew readings. Install on isolatable branches so maintenance can remove the element without draining the whole building. This kit targets trend and allocation metering, not legal custody transfer; state that clearly in customer proposals. Combine with leak ropes when the goal is both consumption anomaly and physical water on the floor.
Specifications
| Parameter | Value |
|---|---|
| Measurement | Inline volumetric flow |
| Pipe size | DN15–DN50 typical (confirm on quote) |
| Output | L/min and cumulative m³ in decoder |
| Wireless | LoRaWAN Class A, EU868 / US915 |
| Battery life | Up to 3 years at 5-min interval |
| Ingress protection | IP65 node; meter IP68 |
* Specifications may vary by model. Contact us for detailed product datasheet.
Applications
- Building makeup and circulation water branches
- Process utility feeds in workshops and light industry
- Irrigation main lines and pump discharge monitoring
- Leak correlation with PS-210 ropes on the same site
- OEM kits for smart building and utility integrators
Decoder & Integration
Flow rate, cumulative volume, battery, and alarm flags are defined in the PS-260 decoder table. Re-zero cumulative totals after known maintenance windows using your LNS downlink policy. Pulse scaling to L/min and cumulative m³ is defined in the decoder table. If your SCADA expects m³/h, convert in the integration layer and document the factor for handover. Factory functional-test records and TTN/ChirpStack decoder maps ship with every kit. Map uplink bytes once on your network server, then reuse the profile across sites.
PS-260 payload decoder guide →Frequently Asked Questions
Explore Other Verticals
Related Products

Multi-Parameter Water Quality Sonde
WQ-500
WQ-500 integrates pH, ORP, conductivity, dissolved oxygen, turbidity, and temperature in one IP68 sonde body. Optional NH₃-N and COD channels scale from compliance lakes to industrial outfalls. RS-485 Modbus RTU is standard; 4–20 mA and SDI-12 profiles are available on the unified probe interface.

Portable Multiparameter Probe
WQ-400
WQ-400 packages the same parameter blocks as fixed sondes into a rugged portable stem for spot sampling, intake audits, and commissioning. Hot-swappable sensor caps shorten field turnaround when a channel is fouled.

Dissolved Oxygen Optical Probe
WQ-310
WQ-310 uses a fluorescence-based DO element immune to flow sensitivity in slow basins. The unified interface presents calibrated mg/L and saturation over Modbus with temperature compensation baked in.

Conductivity & Salinity Probe
WQ-320
WQ-320 reports conductivity, salinity, and temperature on one head. Graphite electrodes resist biofouling better than bare stainless in estuaries. Outputs are scaler-friendly for SCADA via Modbus registers.