LoRaWAN Pipe Pressure Sensor (PS-270)
Model: PS-270
A LoRaWAN pipe pressure sensor — pressure transducer kit — reports bar or kPa on process and utility lines without running analog loops to a PLC. The PS-270 pairs a stainless sensing element with a decoder-ready LoRaWAN node for trend and alarm use in plant rooms and industrial yards. PS-270 closes the gap between a local gauge nobody reads and a fully wired PLC analog loop. Bar readings and threshold flags decode to named fields for pump health, filter monitoring, and utility branch supervision on outdoor LoRaWAN gateways.
Key Features
Manufacturer
ParticleSensing
Certification
ISO 9001 / CE
What is a LoRaWAN pressure transducer?
Pressure transmitters convert mechanical stress in the sensing element to a digital reading. PS-270 installs on isolatable branches with appropriate fittings. The decoder map exports bar with configurable alarm bands. Use for filter differential monitoring, pump discharge pressure, or utility line health — not SIL-rated safety loops unless the datasheet explicitly states so.
Use appropriate isolation valves and snubbers where water hammer is present — pressure spikes beyond range can damage the sensing element. Mount with the process connection pointing down when condensate may collect in the impulse line. PS-270 suits filter differential, pump discharge health, and utility monitoring; do not substitute for SIL-rated safety interlocks unless the datasheet explicitly certifies that use case.
Specifications
| Parameter | Value |
|---|---|
| Principle | Piezo-resistive pressure transducer |
| Range | 0–10 bar typical (confirm on quote) |
| Accuracy | ±0.5 % FS typical |
| Wireless | LoRaWAN Class A, EU868 / US915 |
| Battery life | Up to 3 years at 5-min interval |
| Ingress protection | IP65 node; sensor IP67 |
* Specifications may vary by model. Contact us for detailed product datasheet.
Applications
- Pump discharge and circulation line monitoring
- Filter and strainer differential pressure trends
- Utility water and air compressor receiver monitoring
- Industrial yard process branches with outdoor gateways
- SCADA ingestion via MQTT after LNS decode
Decoder & Integration
Pressure (bar), temperature compensation metadata, battery, and threshold flags are documented for PS-270. Calibrate zero after installation when the line is depressurised and filled. Threshold flags in the payload support high/low alarms without custom byte parsing. Log calibration date in your CMMS when you zero the transmitter after installation. Factory functional-test records and TTN/ChirpStack decoder maps ship with every kit. Map uplink bytes once on your network server, then reuse the profile across sites.
PS-270 payload decoder guide →Frequently Asked Questions
Explore Other Verticals
Related Products
LoRaWAN Food-Grade Needle Temperature Probe Kit
PS-610
Hygienic needle probe for food processing, cold storage, and HACCP product-core temperature.
LoRaWAN Tipping-Bucket Rain Gauge Kit
PS-460
Precision rainfall gauge for irrigation planning, stormwater studies, and ag weather networks.
LoRaWAN Wind Speed & Direction Sensor Kit
PS-450
Wind kit for farm weather stations, rooftop meteorology, and environmental monitoring.
LoRaWAN Ambient Light / PAR Sensor Kit
PS-420
Outdoor light module for crop light management, greenhouse PAR, and weather-station illuminance.