LoRaWAN integration kit
Turnkey wireless edge node with decoder documentation. Prefer a sensing probe when you already have a logger or Modbus master—see complementary SKUs below.

LoRaWAN Pipe Pressure Sensor (PS-270)
Model: PS-270
A LoRaWAN pipe pressure sensor — pressure transducer kit — reports bar or kPa on process and utility lines without running analog loops to a PLC. The PS-270 pairs a stainless sensing element with a decoder-ready LoRaWAN node for trend and alarm use in plant rooms and industrial yards. PS-270 closes the gap between a local gauge nobody reads and a fully wired PLC analog loop. Bar readings and threshold flags decode to named fields for pump health, filter monitoring, and utility branch supervision on outdoor LoRaWAN gateways.
Key Features
Manufacturer
ParticleSensing
Certification
ISO 9001 / CE
What is a LoRaWAN pressure transducer?
Pressure transmitters convert mechanical stress in the sensing element to a digital reading. PS-270 installs on isolatable branches with appropriate fittings. The decoder map exports bar with configurable alarm bands. Use for filter differential monitoring, pump discharge pressure, or utility line health — not SIL-rated safety loops unless the datasheet explicitly states so.
Use appropriate isolation valves and snubbers where water hammer is present — pressure spikes beyond range can damage the sensing element. Mount with the process connection pointing down when condensate may collect in the impulse line. PS-270 suits filter differential, pump discharge health, and utility monitoring; do not substitute for SIL-rated safety interlocks unless the datasheet explicitly certifies that use case.
Specifications
| Parameter | Value |
|---|---|
| Principle | Piezo-resistive pressure transducer |
| Range | 0–10 bar typical (confirm on quote) |
| Accuracy | ±0.5 % FS typical |
| Wireless | LoRaWAN Class A, EU868 / US915 |
| Battery life | Up to 3 years at 5-min interval |
| Ingress protection | IP65 node; sensor IP67 |
* Specifications may vary by model. Contact us for detailed product datasheet.
Applications
- Pump discharge and circulation line monitoring
- Filter and strainer differential pressure trends
- Utility water and air compressor receiver monitoring
- Industrial yard process branches with outdoor gateways
- SCADA ingestion via MQTT after LNS decode
Decoder & Integration
Pressure (bar), temperature compensation metadata, battery, and threshold flags are documented for PS-270. Calibrate zero after installation when the line is depressurised and filled. Threshold flags in the payload support high/low alarms without custom byte parsing. Log calibration date in your CMMS when you zero the transmitter after installation. Factory functional-test records and TTN/ChirpStack decoder maps ship with every kit. Map uplink bytes once on your network server, then reuse the profile across sites.
PS-270 payload decoder guide →Frequently Asked Questions
Explore Other Verticals
Related Products

Multi-Parameter Water Quality Sonde
WQ-500
WQ-500 integrates pH, ORP, conductivity, dissolved oxygen, turbidity, and temperature in one IP68 sonde body. Optional NH₃-N and COD channels scale from compliance lakes to industrial outfalls. RS-485 Modbus RTU is standard; 4–20 mA and SDI-12 profiles are available on the unified probe interface.

Portable Multiparameter Probe
WQ-400
WQ-400 packages the same parameter blocks as fixed sondes into a rugged portable stem for spot sampling, intake audits, and commissioning. Hot-swappable sensor caps shorten field turnaround when a channel is fouled.

Dissolved Oxygen Optical Probe
WQ-310
WQ-310 uses a fluorescence-based DO element immune to flow sensitivity in slow basins. The unified interface presents calibrated mg/L and saturation over Modbus with temperature compensation baked in.

Conductivity & Salinity Probe
WQ-320
WQ-320 reports conductivity, salinity, and temperature on one head. Graphite electrodes resist biofouling better than bare stainless in estuaries. Outputs are scaler-friendly for SCADA via Modbus registers.