LoRaWAN integration kit
Turnkey wireless edge node with decoder documentation. Prefer a sensing probe when you already have a logger or Modbus master—see complementary SKUs below.

LoRaWAN Door & Window Contact Sensor (PS-220)
Model: PS-220
A LoRaWAN magnetic contact sensor logs door and window state for plant rooms, risers, and restricted areas — without running new door-loop wiring. The PS-220 reports open/closed over your existing LoRaWAN network with decoder-ready payloads for TTN and ChirpStack. PS-220 contacts add access context to environmental alarms without pulling new door-loop wiring through risers. They suit plant-room retrofits, cold-store entries, and after-hours alerting when paired with leak or temperature kits on the same LoRaWAN application.
Key Features
Manufacturer
ParticleSensing
Certification
ISO 9001 / CE
What is a LoRaWAN door contact sensor?
Magnetic reed contacts pair a sensor on the frame with a magnet on the moving leaf. When the door opens, the field breaks and the node uplinks an open event. Facility teams use PS-220 contacts on plant-room doors, riser panels, and cold-store entries to correlate access with leak or temperature alarms. Because the kit is wireless, retrofits avoid riser cable pulls that traditional access loops require.
Align the magnet and reed switch gap per the datasheet — oversized gaps on heavy fire doors cause missed open events. For after-hours use, log opens only outside business hours in your rules engine rather than flooding operators during normal shift traffic. Door contacts do not replace intruder alarm loops where regulation requires graded security; they supplement environmental monitoring by tying access to leak or temperature context.
Specifications
| Parameter | Value |
|---|---|
| Detection type | Magnetic reed — open / closed |
| Gap tolerance | Typical ≤ 15 mm (confirm on datasheet) |
| Wireless | LoRaWAN Class A, EU868 / US915 |
| Battery life | Up to 5 years at hourly heartbeats |
| Ingress protection | IP65 node and contact |
| Operating temperature | −20 °C to +60 °C |
* Specifications may vary by model. Contact us for detailed product datasheet.
Applications
- Plant-room and mechanical-space access logging
- Riser cupboard and roof hatch monitoring
- Cold-room and prep-area door status
- After-hours alerts when critical doors open
- Combined dashboards with PS-210 leak ropes on the same gateway
Decoder & Integration
Door state, battery, and frame counter fields are documented in the PS-220 decoder map. Apply the profile once, then fan out open/closed events to your CMMS or BMS. Open and closed states map to boolean fields suitable for BACnet or MQTT fan-out. Include the device EUI in your asset register so moves between gateways stay traceable during facility refits. Factory functional-test records and TTN/ChirpStack decoder maps ship with every kit. Map uplink bytes once on your network server, then reuse the profile across sites.
PS-220 payload decoder guide →Frequently Asked Questions
Explore Other Verticals
Related Products

Multi-Parameter Water Quality Sonde
WQ-500
WQ-500 integrates pH, ORP, conductivity, dissolved oxygen, turbidity, and temperature in one IP68 sonde body. Optional NH₃-N and COD channels scale from compliance lakes to industrial outfalls. RS-485 Modbus RTU is standard; 4–20 mA and SDI-12 profiles are available on the unified probe interface.

Portable Multiparameter Probe
WQ-400
WQ-400 packages the same parameter blocks as fixed sondes into a rugged portable stem for spot sampling, intake audits, and commissioning. Hot-swappable sensor caps shorten field turnaround when a channel is fouled.

Dissolved Oxygen Optical Probe
WQ-310
WQ-310 uses a fluorescence-based DO element immune to flow sensitivity in slow basins. The unified interface presents calibrated mg/L and saturation over Modbus with temperature compensation baked in.

Conductivity & Salinity Probe
WQ-320